Standard Instructions for Using
Rapid Palatal Expander
After the patient and parent are instructed how to activate
the screw, three 1/4 turns are made at this visit at five minute
intervals. Thereafter the patient makes one 1/4 turn each morning and
another 1/4 turn each night. The patient is seen again at the end of
one week to check the progress. If all goes as planned activation is
complete at the end of two weeks.
The appliance is allowed to remain inactive for three months
or more for the bone to fill in. It is best to ligate the screw in place
after the proper expansion is achieved, to avoid the possibility of the
screw backing up. It is also a good idea to X-ray the palate before
removing the appliance to be sure the suture has filled in with bone.
Each time the
swivel key is inserted into the hole in the
screw, and turned until the key touches the housing. That is considered to be
one turn. This is actually only one 1/4 revolution of the entire screw
shaft. For each full revolution of the screw, one mm of expansion is
achieved.
The four type of screws that we use are:
standard RPE screw
Swivel Keys used to
adjust safely in mouth
10 mm maximum expansion @ 44 turns
(this one comes out of the housing 52 turns)
13 mm maximum expansion @ 62 turns
(screw locks and does not exit housing)
Super Screws use a wrench
12 mm
16/18 mm
(each line on screw is 2mm)
(each wrench swing is 1/12 mm)
pdf file of
instructions
Fan RPE
distances moved will vary
dependent on placement in palate
Haas Screw
13mm